Prefabricated Substation (American type)
Prefabricated Substation (American type) It is a kind of box-type substation and distribution product which puts the high-voltage switchgear, transformer and protection fuse in the oil tank. High voltage side rated voltage ≤ 40.5kV, low voltage side rated voltage 0.22/0.4/0.69kV, rated frequency 50Hz/60Hz outdoor three-phase AC power distribution system, rated capacity ≤ 1200kVA, independent complete sets of power distribution equipment. Widely used in all kinds of residential, commercial buildings, public facilities, industrial and mining enterprises and urban and rural power grids.
Product Features
Compact structure, the volume is one-third of the European box variable with the same function, and the weight is one-half.
High-voltage switch is installed in the transformer oil, fully closed structure, oil and air are fully isolated, slowing down the oxidation process and water vapor intervention, improving the stability, reliability and safety of high-voltage system equipment.
Low noise: the noise is 7-10dB lower than ordinary box variable.
Anti-corrosion and dust-proof: It adopts powder coating and anti-corrosion coating treatment. After long-term use, the surface is still beautiful and intact.
It can realize telemetry, remote control and real-time monitoring of the substation.
Technical Parameter
Prefabricated Substation (American type) | ||
Enclosure Characteristics | ||
Rated capacity(kVA) | ≤1200 | |
Voltage | High voltage(kV) | ≤40.5 |
Low voltage(kV) | 0.22/0.4/0.69 | |
Enclosure type | Material type | stainless steel/Galvanized Iron steel/Cold-rolled steel |
Thicknesses(mm) | ≤3 | |
Out enclosure protection level | IP44 / IP54 | |
Rated frequency(Hz) | 50 / 60 | |
Forms of operational control | Manual / Motorised / Remote | |
External dimension | Customised on request | |
Transformer part | ||
Transformer type | Oil-type | |
Cooling type | Oil:ONAN / ONAF | |
Tap regulation voltage | ±5% or ±2*2.5% | |
Noise level(db) | ≤55 | |
High voltage switch part | ||
Type | Oil-immersed Load break switch-fuse combination | |
Dielectric medium | Oil | |
Current limiting fuse rated current(A) | ≤125 | |
Rated short-circuit withstand current(kA) | 25 / 31.5 | |
Low voltage switch part | ||
Type | Drawer Type Switch / Fixed Type Switch | |
Rated current(A) | ≤2000 | |
Number of circuits | 6~20 | |
Switch Type | ACB / MCCB / MCB | |
Declaration: This product is a custom class, special requirements can be customised according to customer requirements. |